NPK Morsvyazavtomatika - Marine Electronics

CH-105

Automatic battery charger

  • Description
  • Technical specification
  • Downloads
  • Support
CH-105 Automatic Charger is designed for automatic charging of the storage batteries of the shipboard equipment, as well as other industrial and transport equipment.
  • Overall and mounting dimensions
  • Functional scheme
  • Wiring diagram
General characteristics
Overall dimensions 345x310x140 mm
Ingress protection rating IP 22
Storage temperature -60…+70 °С
Operating temperature -20…+55 °С
Weight not more than 7 kg
Electrical characteristics
Model CH-105 CH-105-24 CH-105-2412A CH-105-110 VDC CH-105-220 VDC
Supply voltage ~110/220 V, 50/60 Hz 24 VDC (19…72 V) 110 VDC 220 VDC
Maximum output power 600 W 500 W 350 W 500 W 420 W
Charging current 1…20 A 1…16 A 1…12 A 1…16 A 1…14 A
Charging voltage 9…30 VDC (for charging the battery with a working voltage of 12 V or 24 V)
Standard capacity of charged batteries 40-200 A*h 40-160 A*h 40-120 A*h 40-160 A*h 40-140 A*h
    Built-in protection
  • reverse polarity protection;
  • excessive voltage of supply network;
  • excessive current in AB circuit (overload / short-circuit);
  • connection of AB with reverse polarity;
  • protection of battery from deep discharge (connected function);
  • protection of battery from overheating (with use of thermal sensor DTS-135).