CH-105
Automatic battery charger
- Description
- Specifications
- Files
- Support
- Where to buy
The unit is equipped with a built-in control and indication panel to set the charging modes and display the storage battery status. The CH-105 can be optionally equipped with the external control panel BCP-136. Install in a dry environment (IP22). The device has a reverse polarity protection of the main power and storage battery, and a current overload protection. Deep discharge and overheat protection are optional (provided that the thermal sensor DTS-135 is used).
Parameter |
Value |
|
Input voltage, VAC, frequency 50 (60) Hz |
110 (99 to121) 1); 220 (198 to 242) 1) |
|
Power consumption, W |
690 |
|
Max. output power, W |
600 |
|
Charge voltage DC, V |
9 to 30 |
|
Charge current, А |
0.2 to 20.0 |
|
Rated capacity of recharged batteries, А·h |
max. 200 |
|
Max. charge time of SB, h |
10 |
|
Measurement error |
current, А |
±0.2, max. |
voltage, V |
±0.1, max. |
|
Accuracy ofadjustment |
current, А |
0.1 |
voltage, V |
0.1 |
|
Alarm signaling |
Built-in: relay contacts, sound signaling, light signaling; External (connected) devices: AU-106 or AU-206, BCP-136 |
|
Protection degree |
IP22 |
|
Weight, kg |
7.1 |
|
Operating temperature, °С |
–15 to +55 |
|
Limiting temperature, °С |
–60 to +70 |
|
Mounting |
wall |
|
1) Supply voltage range is given in parenthesis. |
- Built-in protection
- reverse polarity protection
- power loss protection
- excessive current in AB circuit (overload / short-circuit)
- connection of AB with reverse polarity
- deep discharge protection (optional function)
- overheating protection (using the DTS-135 thermal sensor)