NPK Morsvyazavtomatica
|
NPK Morsvyazavtomatica - Marine Electronics
Unicont, Saint-Petersburg

SCS-1002

Hospital and refrigerator alarm system

  • Description
  • Technical specification
  • Downloads
  • Support
The SCS-1002 is designed for application on sea and river-going vessels at any navigation area. The system supplies signals to the watch officer station from the button controllers, located in the refrigerator machines rooms, ship’s hospital and other areas where restricted mobility or life threat occur. The SCS-1002 can be used for any other purposes, where remote alarm announcement of the watch stations is required.
Primary system characteristics
No. in–call posts controlled 1 / 5 / 10 / 32
Maximal no. of in–call posts included up to 128 (max. 32 simultaneously displayed on the screen)
Power supply voltage
  • 24 (18–36) VDC – for system devices;
  • 24 VDC or 220 VAC, 50 Hz – for annunciation devices.
Integral protection of the system devices
  • galvanic isolation from the mains;
  • accidental polarity reversal protection;
  • signal loop galvanic isolation;
  • in–call button loop interruption prevention (control resistor present, integrated with buttons);
  • button post controllers interconnection supervised.
Power consumption defined with the total power consumed with all the devices included into the delivery set of the system
Ingress protection grade IP22, IP56
Operational temperature
  • -15…+55 °C – for the system devices installed in the internal vessel premises;
  • -40…+55 °C – for the system devices exposed on board;
  • -40…+125 °C – for heat–resistant system devices.
  • Wiring diagram