UPS 20 kW
Uninterruptible power supply unit 20 kW
Description
Uninterruptible power supply unit is designed to provide consumers with regulated three-phase current in the event of power mains failure or significant deterioration of electric energy quality of external network. Operation time of UPS depends on the supplied components.
Features
- Automatic switching from external power to own accumulator batteries (AB) in the event of power mains failure or power shutdown;
- Charge of own batteries when external power mains is available;
- Power supply of consumers with regulated current and simultaneous charge of own batteries;
- Automatic heating of AB when external power is available.
Technical specifications
Rated power | 20.5 kW |
Operation time at rated power from AB | min. 60 min. (operation time can be increased if a battery with higher capacity is used) |
Time of automatic switching from external network to AB | max. 100 ms |
Time of readiness to connect max. load at cold start | max. 3 s |
Input | 3ph+ N + PE |
Input voltage | 400 V |
Input voltage deviation | ±5% |
Input frequency | 45-55 Hz |
Output | 3ph + N + PE |
Signal waveform | pure sinewave |
Output linear voltage | 400 V |
Output phase-to-neutral voltage | 235 V |
Max. output phase-to-line voltage | 31 А (at cos φ = 0.95) |
Output frequency when operating from AB | 50 Hz |
Output voltage deviation | from –15% to +10% |
Output frequency deviation | ±0.2% |
Type of AB | LiFePО4 |
Voltage | 48 V |
AB capacity | 840 А*h on the basis of 100 Ah prismatic cells (types with AB EVE, capacity 105, 280 or 304 А*h – at option) |
AB energy | 40.32 kW*h |
Battery life | 15 years, min. 5000 cycles (after 5000 cycles, cells keep 80% of discharge capacity) |
IP rating | IP20 and more (on request) |
Efficiency | min. 83% |
Operating temperature | –40…+40°С |
Casing material | metal |
Composition of equipment and outline dimensions (W х L х H)
- Invertor switchboard: 331.5 х 345.0 х 342.0 mm
- Battery switchboard: 715.0 х 340.0 х 315.0 mm
- Remote panel: 140.0 х 66.4 х 89.6 mm
Weight
- Invertor switchboard: 173.50 kg
- Battery switchboard: 315.00 kg
- Remote panel 1.42 kg
Additional information
- Light and sound indication of system status (voltage and frequency, power consumption of load, etc.)
- Remote control of technical condition, SoC and output parameters via Ethernet
- Heating switches on automatically when AB temperature decreases to +5 °С
- Remote control panel (on customer request)
- Automatic tracking of running hours
- Integrated battery balancing system
- Cold start
- EPO system (emergency power off)
- AB protection against overvoltage and deep discharge
- Transportation with AB