UPS 54 kW

Uninterruptible power supply unit 54 kW

Description

Uninterruptible power supply unit is designed to provide consumers with regulated three-phase current in the event of power mains failure or poor quality of electric power. Operation time of UPS depends on the components.

Features

  • Automatic transfer from external power to own batteries (AB) in the event of power mains failure or when the parameters are outside the limits;
  • charge of own AB if external power network is available;
  • power supply to consumers (regulated current) and simultaneous charge of own AB;
  • automatic heating of batteries if external power is available.

Technical specifications

Rated power  54 kW
Operation time at rated power from AB  min. 15 minutes (time can be increased if a battery of higher capacity is used)
Max. time of automatic switching from external mains to AB  100 ms
Time of readiness to connect max. load at cold start  max. 3 s
Input  3ph + N + PE
Input voltage  400 V
Input voltage deviation  ±5%
Input frequency  45-55 Hz
Output  3ph + N + PE
Output signal waveform  pure sinewave 
Output linear voltage  400 V
Output phase voltage  235 V
Max. output phase current  74 А
Output frequency when operating from AB  50 Hz
Output voltage deviation  from –15% to +10%
Output frequency deviation  ±0.2%
Type of AB  LiFePО4
Voltage  48 V
AB capacity  912 А*h on the basis of 100 Ah prismatic cells (designs with AB EVE, capacity 105, 280 or 304 А*h – at option)
AB energy  43.77 kW*h
Battery life  15 years, min. 5000 cycles (after 5000 cycles, cells save 80% of discharge capacity)
IP rating  IP20 and higher (on customer request)
Efficiency  min. 83%
Operating temperature  –40…+40 °С
Casing material  metal

Composition of equipment, outline dimensions (W х L х H)

  • Invertor switchboard: 663.0 х 690.0 х 684.0 mm
  • Battery switchboard: 1430.0 х 680.0 х 630.0 mm
  • Remote panel: 140.0 х 66.4 х 89.6 mm

Weight

  • Invertor switchboard: 347.00 kg
  • Battery switchboard: 630.00 kg
  • Remote panel: 1.42 kg    

Additional information

  • Light and sound indication of system status (voltage and frequency, power consumption of load, etc.)
  •   Remote control of technical condition, SoC and output parameters via Ethernet
  •   Remote control panel (on customer request)
  •   Heating switches automatically when AB temperature decreases to +5°С
  •   Automatic monitoring of running hours
  •   Integrated battery balancing system
  •   Cold start
  •   EPO system (emergency power off)
  •   AB protection against overvoltage and deep discharge
  •   Transportation with AB