UniPower BOX
High-powered lithium-ion (Li-ion) battery modules LiFePO4.
Made in Russia
UniPower BOX modules are the perfect solution for Individual Households and SME ESSs. Turn-key, scalable and size-efficient UniPower BOX allows simple integration with all kinds of private generating power systems to store excess energy and optimum distribution.
Application:
- Emergency energy storage
- Uninterruptible power supply units
- Smooth out peaks
- Excess energy storage
- Standby drive systems
- Various medium power and energy storages easy scalable (fold) by 10 kw·h
Advantages of Li-ion technologies:
- Reduced weight and volume
- Ultra long life and many life cycles
- Shorter charge time
- Operation in any orientation
- High power
Advantages:
- Full cycle of electric drive in low dimensions and weight even on the existent projects
- Stable load for fuel saving and reducing time of genset operation
- Stable inside power from shore systems
Safety:
- Li-ion batteries LiFePO4 are one of the safest on the market
- NO overheat or fire detected while providing the following tests:
- Impact
- Deformation
- Overcharge
- Short circuit
- Puncture
- Built-in system to monitor battery parameters, balancing and fuse
- Built-in venting system
Specifications:
Electrical characteristics (+22ºС) |
||
---|---|---|
Voltage |
96 V |
|
Density |
9.6 kW·h |
|
Power |
28.8kW / 48kW – 30 sec for impulse discharge |
|
Current (1С) |
100 A |
|
Nominal specific energy |
80 W·h/kg |
|
Nominal energy density |
111 W·h/l |
|
Nominal mode |
Charge |
0.5 С |
Discharge |
1 С |
|
Max continuous |
Charge |
2 С |
Discharge |
3 С |
|
Max discharge, not more 30 sec |
up to 5С |
|
Cycle life 1С, +22 ºС, 80% DOD |
5000 |
Mechanical characteristics | ||
---|---|---|
Weight |
120 kg |
|
Dimensions |
454х254х748.5 mm |
Temperature | ||
---|---|---|
Optimum temperature range |
+19ºС / +22ºС |
|
Charge temperature |
0°С / + 45°С |
|
Discharge temperature |
- 25°С / + 50°С |
|
Storage temperature, not exceeding 1 year |
- 25°С / + 35°С |
|
Life time (if operated according to Technical manual), not less than |
10 years |